Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 18819, 2021 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-34552130

RESUMO

Nanostructured cell culture substrates featuring nanowire (NW) arrays have been applied to a variety of basic cell lines and rodent neurons to investigate cellular behavior or to stimulate cell responses. However, patient-derived human neurons-a prerequisite for studying e.g. neurodegenerative diseases efficiently-are rarely employed due to sensitive cell culture protocols and usually long culturing periods. Here, we present human patient induced pluripotent stem cell-derived neurons cultured on densely-spaced spiky silicon NW arrays (600 NWs/ 100 µm[Formula: see text] with NW lengths of 1 µm) which show mature electrophysiological characteristics after only 20 days of culturing. Exemplary neuronal growth and network formation on the NW arrays are demonstrated using scanning electron microscopy and immunofluorescence microscopy. The cells and neurites rest in a fakir-like settling state on the NWs only in contact with the very NW tips shown by cross-sectional imaging of the cell/NW interface using focused ion beam milling and confocal laser scanning microscopy. Furthermore, the NW arrays promote the cell culture by slightly increasing the share of differentiated neurons determined by the quantification of immunofluorescence microscopy images. The electrophysiological functionality of the neurons is confirmed with patch-clamp recordings showing the excellent capability to fire action potentials. We believe that the short culturing time to obtain functional human neurons generated from patient-derived neural progenitor cells and the robustness of this differentiation protocol to produce these neurons on densely-spaced spiky nanowire arrays open up new pathways for stem cell characterization and neurodegenerative disease studies.


Assuntos
Diferenciação Celular , Células-Tronco Pluripotentes Induzidas/fisiologia , Nanofios , Células-Tronco Neurais/fisiologia , Silício , Humanos , Células-Tronco Pluripotentes Induzidas/ultraestrutura , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Células-Tronco Neurais/ultraestrutura
2.
Adv Healthc Mater ; 9(1): e1901342, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31794161

RESUMO

Implanted pacemakers are usually bulky and rigid electronics that are constraint by limited battery lifetimes, and need to be installed and repaired via surgeries that risk secondary infection and injury. In this work, a flexible self-powered photoelectric cardiac stimulator is demonstrated based on hydrogenated amorphous Si (a-Si:H) radial p-i-n junctions (RJs), constructed upon standing Si nanowires grown directly on aluminum thin foils. The flexible RJ stimulators, with an open-circuit voltage of 0.67 V and short-circuit current density of 12.7 mA cm-2 under standard AM1.5G illumination, can be conformally attached to the uneven tissue surface to pace heart-beating under modulated 650 nm laser illumination. In vivo pacing evaluations on porcine hearts show that the heart rate can be effectively controlled by the external photoelectric stimulations, to increase from the normal rate of 101-128 beating min-1 . Importantly, the a-Si:H RJ units are highly biofriendly and biodegradable, with tunable lifetimes in phosphate-buffered saline environment controlled by surface coating and passivation, catering to the needs of short term or lasting cardiac pacing applications. This implantable a-Si:H RJ photoelectric stimulation strategy has the potential to establish eventually a self-powered, biocompatible, and conformable cardiac pacing technology for clinical therapy.


Assuntos
Estimulação Elétrica/métodos , Marca-Passo Artificial , Silício/química , Alumínio/química , Animais , Estimulação Elétrica/instrumentação , Eletrocardiografia , Coração/fisiologia , Frequência Cardíaca , Luz , Masculino , Nanofios/química , Fibras Ópticas , Energia Solar , Suínos
3.
ACS Nano ; 13(9): 10359-10365, 2019 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-31480845

RESUMO

The actual light absorption photovoltaic responses realized in three-dimensional (3D) radial junction (RJ) units can be rather different from their planar counterparts and remain largely unexplored. We here adopt a laser excitation photoelectric microscope (LEPM) technology to probe the local light harvesting and photoelectric signals of 3D hydrogenated amorphous silicon (a-Si:H) RJ thin film solar cells constructed over a Si nanowire (SiNW) matrix, with a high spatial resolution of 600 nm thanks to the use of a high numerical aperture objective. The LEPM scan can help to resolve clearly the impacts of local structural damages, which are invisible to optical and SEM observations. More importantly, the high-resolution photoelectric mapping establishes a straightforward link between the local 3D geometry of RJ units and their light conversion performance. Surprisingly, it is found that the maximal photoelectric signals are usually recorded in the void locations among the standing SiNW RJs, instead of the overhead positions above the RJs. This phenomenon can be well explained and reproduced by finite element simulation analysis, which highlights unambiguously the dominant contribution of inter-RJ-unit scattering against direct mode incoupling in the 3D solar cell architecture. This LEPM mapping technology and the results help to achieve a straightforward and high-resolution evaluation of the local photovoltaic responses among the 3D RJ units, providing a solid basis for further structural optimization and performance improvement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...